mcr PS

Fire protection collar
  • Construction
    mcr PS fire collars consist of one or more layers of intumescent inserts placed inside a housing made of galvanized steel sheet or stainless steel.
  • Housing and fastening
    The housing is equipped with a clasp for joining the collar ends and stabilizing it on the pipe, as well as mounting brackets for fixing the collar to the partition.
  • Adaptation
    The number of mounting brackets is adjusted to the size of the collar.
Do you need this solution?
Request an Offer

Construction and installation of mcr PS fire collars

mcr PS fire collars consist of one or more layers of intumescent inserts placed inside a housing made of galvanized steel sheet or stainless steel. The housing is equipped with a clasp for joining the collar ends and stabilizing it on the pipe, as well as mounting brackets for fixing the collar to the partition. The number of mounting brackets is adjusted to the collar size.

Request an Offer

Applications

Fire protection for service penetrations through walls and floors:

  • combustible pipes with diameters up to 250 mm (PVC-U, PVC-C, PE-HD, PE, ABS, SAN+PVC, PP-R)
  • pipe bundles up to 4 × 75 mm
  • combustible pipes with diameters up to 160 mm installed at an angle to the partition
  • combustible pipes in mixed service penetrations

Features

mcr PS collars provide fire resistance up to EI120 in walls and floors that meet the required thickness and density parameters. During a fire, the intumescent inserts expand, effectively sealing the opening left by the burned-out installation, ensuring reliable fire protection.

 

Classified up to EI120 when installed in rigid walls of at least 100 mm thickness. These may be made of concrete, reinforced concrete, aerated concrete, solid brick, hollow brick, or perforated block, with a minimum density of 600 kg/m³.

Can also be used in flexible walls of at least 100 mm thickness, constructed on a wooden or steel frame with a minimum of two layers of type F or DF gypsum plasterboards on each side (in accordance with EN 520).

 

Suitable for rigid floors of at least 150 mm thickness, made of concrete, reinforced concrete, or aerated concrete with a minimum density of 600 kg/m³. In case of fire, when the temperature exceeds 140°C, the intumescent inserts in the collar expand, sealing the opening after the burned-out installation.

parametry_techniczne_mcr_PS ENG

Instructions and downloads